PE Civil Structural Practice Exams gives you two full-length practice forms to sit under exam timing, then shows you exactly where each point went.
- 160 questions in two 80-question forms, matched to the NCEES PE Civil: Structural exam topics
- A worked solution for every question, with the PE Civil Reference Handbook 2.2 section or design-code provision it uses
- Why each wrong option is wrong, so a miss tells you what to fix
- TI-36X Pro keystrokes for the calculations
- A score-and-repair page for each form and a handbook navigation guide
- 184-page paperback (8.5 × 11 in.) or Kindle; updated November 2026
Disclosure: We write and publish this book. The Amazon links are affiliate links: if you buy through them, Amazon pays us a small referral fee on top of the book royalty, at no extra cost to you. See our disclosure page.
Look inside
These are unedited pages from the current paperback. Select a page to see it full size.
Try three questions from the book
Each sample below is copied from the book as printed, including its practice time budget, figure and worked solution. Work it on paper first, with your handbook and calculator, then open the solution.
Sample 1: Form A, question 1
A W12×65 column has A = 19.1 in² and ry = 3.02 in. Its effective length, restrained axis and material properties are shown. Use the supplied AISC 360-16 E3 model: λ = KL/r; Fe = π²E/λ²; Fcr = (0.658Fy/Fe)Fy when λ ≤ 4.71 √(E/Fy), otherwise Fcr = 0.877 Fe. The governing slenderness and critical stress are most nearly:
Show the answer and the worked solution from the book
Answer: A
Reference: AISC 360-16 Section E3 — Flexural Buckling of Compression Members
Key idea: Slenderness: . Euler stress: ksi. Since , inelastic buckling applies: . . ksi.
- KL/r = 18(12)/3.02 = 216/3.02 = 71.5
- = (29,000)/ = 286,200/5,112 = 56.0 ksi
- Check: 71.5 < 4.71 √(29000/50) = 113.4 → inelastic buckling
- = × = × 50 = 34.4 ksi
Why the other options are wrong
- Option B: uses an incorrect radius or effective length; the stated weak-axis slenderness is 71.523.
- Option C: has the right slenderness but the wrong stress: the inelastic expression gives 34.398 ksi.
- Option D: uses a slenderness of 85 instead of 71.523.
TI-36X Pro keystrokes
- Slenderness: 18 × 12 ÷ 3.02 enter → 71.5231788. Store → a.
- Euler stress: π xʸ ( 2 ) → × 29000 ÷ a xʸ ( 2 ) → enter → 55.95052 ksi. Store → b.
- Branch limit: 4.71 × 2nd √ ( 29000 ÷ 50 ) → enter → 113.431821.
- Inelastic critical stress: 0.658 xʸ ( 50 ÷ b ) → × 50 enter → 34.3976019 ksi.
Sample 2: Form A, question 2
The pin-jointed planar truss shown has a span of 60 ft with 6 panels at 10 ft each and a height of 10 ft. A single concentrated load of 30 kips is applied at the third panel point from the left (midspan) on the bottom chord. Using the method of sections, the force in bottom chord member CD, from x = 30 ft to x = 40 ft is most nearly:
Show the answer and the worked solution from the book
Answer: C
Reference: PE Civil Reference Handbook 2.2 — 1.5.11.2 Plane Truss: Method of Sections (p. 23)
Key idea: Reactions: By symmetry, kips. Cut through the truss just to the right of midspan (between panels 3 and 4), severing the top chord, bottom chord, and diagonal. Take moments about the top chord joint at panel 4 (at ft, ft) to isolate the bottom chord force. Left of the cut: kips up at , and the 30 kip load down at . . . . kips (tension).
- Calculate reactions: = = 30/2 = 15 kips
- Cut through truss just right of midspan, isolate left portion
- Sum moments about top chord joint at panel 4 (x = 40, y = 10)
- 15(40) − 30(10) = (10) → = 300/10 = 30.0 kips (tension)
Why the other options are wrong
- Option A: (15.0 kips) confuses the support reaction (R = 15 kips) with the bottom chord force.
- Option B: (22.5 kips) uses an incorrect moment arm in the method of sections.
- Option D: (45.0 kips) uses the beam midspan moment 15(30) divided by the 10 ft height instead of taking moments about the joint where the other two cut members intersect.
TI-36X Pro keystrokes
- Bottom-chord force: ( 30 ÷ 2 × 40 − 30 × 10 ) ÷ 10 enter → 30 kips.
- The cut-section equilibrium gives tension.
Sample 3: Form B, question 41
A braced steel column is checked under two complete factored load cases. Available strengths are Pc = 500 kips, Mcx = 250 kip-ft and Mcy = 140 kip-ft; the local section axes are identified in the plan view. Case G has Pr = 60 kips and a first-order moment of 175 kip-ft about local x. Case W has Pr = 160 kips and a horizontal 10-kip force toward east applied 12 ft above the fixed base; there is no other first-order moment in W. For each nonzero moment component use the stipulated nonsway second-order model , with Pr in kips. No further load factors apply. The AISC 360-16 H1.1 summary is: for , utilization is ; below 0.20 it is . Other checks are satisfied. Which case governs, and what is its utilization?
Show the answer and the worked solution from the book
Answer: D
Reference: AISC 360-16 Section H1.1, Equations H1-1a and H1-1b; stipulated second-order demand model
Key idea: G has axial ratio 0.12 and uses the low-axial branch: amplified Mx is kip-ft, so utilization is 0.80468. In W, the east-directed horizontal force acts along local x;its vertical lever arm creates bending about local y, not local x. Therefore first-order My is kip-ft and amplified My is kip-ft. W has axial ratio 0.32 and uses the other interaction branch: . It governs and exceeds 1.00 despite having a smaller moment magnitude than G. Option D is correct.
- The east-directed force acts along local x; its vertical lever arm creates bending about local y.
- Derive W first-order moment kip-ft; amplify it to kip-ft.
- For G, axial ratio selects the low-axial branch; use Mcx = 250 kip-ft to obtain .
- For W, axial ratio selects the high-axial branch; use Mcy = 140 kip-ft to obtain .
- W governs and exceeds unity. A compares raw moments, B omits amplification, and C uses the wrong axis capacity.
Why the other options are wrong
- Option A: compares moment magnitudes without their axis capacities and axial-force interactions.
- Option B: omits W amplification, obtaining 1.08190.
- Option C: uses the major-axis capacity 250 instead of the appropriate minor-axis 140, obtaining 0.82794.
TI-36X Pro keystrokes
- G utilization: 60 ÷ ( 2 × 500 ) + 175 ÷ ( 1 − 60 ÷ 1000 ) ÷ 250 enter → 0.804680851.
- W utilization: 160 ÷ 500 + 8 ÷ 9 × 10 × 12 ÷ ( 1 − 160 ÷ 1000 ) ÷ 140 enter → 1.22702948.
- W bends about local y and uses its lower moment capacity; W governs.
How the book and the study app fit together
The book’s questions come from the same reviewed PE Civil Structural question bank as the FE Test Prep study app. The book arranges 160 of them into two fixed, timed forms with every solution printed, which suits studying on paper with the handbook open. The app adds the rest of the bank, timed simulations, topic tracking and calculator walkthroughs. If you already use the app, some book questions will be familiar.
Found a problem in a printed question? Corrections for every edition are listed on our errata page.
Related
- All FE and PE practice exam books
- PE Civil Structural study guide
- PE Civil Structural practice problems
- Free 12-question PE Civil Structural practice set
Get the book
Sit Form A under exam timing, score it with the score-and-repair page, fix what it shows, then sit Form B.